T48150 150Ah 3U Telecom Battery
The T48150 is a 150Ah LiFePO4 telecom backup battery in a 3U rack format. Confirm the system voltage, rectifier settings and communication requirements for your installation.
The T48150 is a 150Ah LiFePO4 telecom backup battery in a 3U rack format. Confirm the system voltage, rectifier settings and communication requirements for your installation.

The battery uses LFP (lithium iron phosphate) chemistry. Its BMS monitors temperature, current, voltage, state of charge and state of health to support battery protection. Review the model-specific operating limits and test documentation for the intended application.
Low maintenance requirements and straightforward installation help reduce routine service work.
| SPECIFICATION | BASIC PARAMETERS | T48150 |
| Nominal | Nominal Voltage(V) | 48 |
| Nominal Capacity(Ah) | 150 | |
| Nominal Charge Current (A) | 100 | |
| Nominal Discharge Current(A) | 100 | |
| Physical | Dimension(mm) | 482*420*135 |
| Weight(Kg) | 48 | |
| Electrical | Discharge Voltage(V) | 42~54 |
| Charge Voltage(V) | 52.5~54 | |
| Peak Discharge Current(A) | 150@3S | |
| Peak Charge Current(A) | 100@3S | |
| Others | Communication | RS232, RS485 |
| Charging Temperature | 0℃~50℃ | |
| Discharging Temperature | -20℃~50℃ | |
| Shelf Temperature | -20℃~60℃ | |
| Certification | CE/UN38.3 | |
| Design life | 10+Years(25℃177F) | |
| Cycle Life | >6000(80%DoD) |
Review the T48150 for the applications below after confirming voltage, rectifier or UPS compatibility, rack requirements and the intended backup duty.
The standard 3U design simplifies installation in existing telecom and server cabinets.
Confirm the system voltage and charging settings for the selected T48150 configuration before choosing the rectifier or UPS interface.
The 150Ah configuration provides substantial energy storage without requiring a large floor-standing battery bank.
The integrated BMS monitors battery status and helps prevent damage caused by abnormal operating conditions.
LiFePO4 chemistry reduces routine maintenance requirements compared with conventional lead-acid batteries.
For projects requiring multiple batteries, review the permitted configuration, controls and protection requirements with Wiren.
Share the required voltage, communication, terminal layout, cabinet integration and monitoring functions for a configuration review.
The battery should be installed by qualified electrical or energy storage personnel.
Before installation, confirm:
The battery should be installed in a dry, clean and ventilated location away from direct sunlight, heat sources, standing water and corrosive substances.
Adequate space should be reserved for cable connection, inspection and battery removal.
It is designed for telecom networks, data centers, server rooms, industrial control systems and other facilities where continuous power availability is essential.
For project selection, send us your UPS model, system voltage, connected load, required backup time, communication protocol and order quantity. We can recommend a suitable battery configuration for your backup power system.