Wiren T48150 150Ah 3U telecom backup battery
Black Wiren rack battery with a finned front panel, terminal cover and metal handles.
Wiren T48150 150Ah 3U telecom backup battery
Black Wiren rack battery with a finned front panel, terminal cover and metal handles.

T48150 150Ah 3U Telecom Battery

The T48150 is a 150Ah LiFePO4 telecom backup battery in a 3U rack format. Confirm the system voltage, rectifier settings and communication requirements for your installation.

Request a Configuration →  |  Explore Related Batteries

Telecom Backup Integration

 

48v 100AH

 

Battery & Monitoring Features

 

The battery uses LFP (lithium iron phosphate) chemistry. Its BMS monitors temperature, current, voltage, state of charge and state of health to support battery protection. Review the model-specific operating limits and test documentation for the intended application.

Low maintenance requirements and straightforward installation help reduce routine service work.

 

T48150 Specifications

 

SPECIFICATION BASIC PARAMETERS T48150
Nominal Nominal Voltage(V) 48
Nominal Capacity(Ah) 150
Nominal Charge Current (A) 100
Nominal Discharge Current(A) 100
Physical Dimension(mm) 482*420*135
Weight(Kg) 48
Electrical Discharge Voltage(V) 42~54
Charge Voltage(V) 52.5~54
Peak Discharge Current(A) 150@3S
Peak Charge Current(A) 100@3S
Others Communication RS232, RS485
Charging Temperature 0℃~50℃
Discharging Temperature -20℃~50℃
Shelf Temperature -20℃~60℃
Certification CE/UN38.3
Design life 10+Years(25℃177F)
Cycle Life >6000(80%DoD)

Applications

Review the T48150 for the applications below after confirming voltage, rectifier or UPS compatibility, rack requirements and the intended backup duty.

Telecommunications

  • Mobile base stations
  • Telecom switching rooms
  • Transmission stations
  • Fiber network equipment
  • Remote communication sites

Data Centers

  • Server backup
  • Network equipment backup
  • Rack-mounted UPS systems
  • Edge computing facilities
  • Storage and processing infrastructure

Commercial Facilities

  • Office network rooms
  • Financial service systems
  • Retail data equipment
  • Security and monitoring centers
  • Communication control rooms

Industrial Systems

  • PLC and automation equipment
  • Industrial computers
  • Emergency control systems
  • Process monitoring equipment
  • Factory communication networks

Renewable Energy Systems

  • Solar telecom stations
  • Hybrid grid and solar backup
  • Remote monitoring stations
  • Off-grid communication equipment

Benefits for System Integrators and Project Buyers

Compact Rack Integration

The standard 3U design simplifies installation in existing telecom and server cabinets.

Flexible Voltage Selection

Confirm the system voltage and charging settings for the selected T48150 configuration before choosing the rectifier or UPS interface.

High Backup Capacity

The 150Ah configuration provides substantial energy storage without requiring a large floor-standing battery bank.

Intelligent Protection

The integrated BMS monitors battery status and helps prevent damage caused by abnormal operating conditions.

Reduced Maintenance

LiFePO4 chemistry reduces routine maintenance requirements compared with conventional lead-acid batteries.

Suitable for Modular Projects

For projects requiring multiple batteries, review the permitted configuration, controls and protection requirements with Wiren.

Customizable System Integration

Share the required voltage, communication, terminal layout, cabinet integration and monitoring functions for a configuration review.

Installation Requirements

The battery should be installed by qualified electrical or energy storage personnel.

Before installation, confirm:

  • UPS or rectifier voltage compatibility
  • Charging voltage range
  • Maximum charging current
  • Maximum discharge current
  • Communication compatibility
  • Rack dimensions and load capacity
  • Cabinet ventilation
  • Cable size and cable length
  • DC breaker or fuse rating
  • Correct positive and negative polarity
  • Grounding requirements
  • Local electrical and fire safety regulations

The battery should be installed in a dry, clean and ventilated location away from direct sunlight, heat sources, standing water and corrosive substances.

Adequate space should be reserved for cable connection, inspection and battery removal.

It is designed for telecom networks, data centers, server rooms, industrial control systems and other facilities where continuous power availability is essential.

For project selection, send us your UPS model, system voltage, connected load, required backup time, communication protocol and order quantity. We can recommend a suitable battery configuration for your backup power system.

 

Discuss Your Telecom Battery Project →