LiFePO4 UPS Battery Systems
LiFePO4 UPS Battery Systems

LiFePO4 UPS Batteries: 1C, 2C and 4C Options

Wiren’s LiFePO4 UPS battery range includes UPS1C6, UPS2C6, UPS4C2 and UPS4C5, with model-specific 1C, 2C and 4C discharge configurations for engineered backup systems.

Request a UPS Battery Configuration   Explore Energy Storage Systems

  • Data centers IT infrastructure Datacenter

  • Hospital

  • Commercial building

  • Transportation & smart infrastructure

LiFePO4 Battery Options for UPS Projects

Compare module and rack arrangements for critical-load backup in data centers, hospitals and commercial buildings. Selection starts with the connected UPS and the required discharge duty, not nominal energy alone.

UPS Battery Model Comparison

Specification UPS1C6 UPS2C6 UPS4C2 UPS4C5
Listed discharge rate 1C 2C 4C 4C
Cell specification 3.2 V 100 Ah 3.2 V 100 Ah 3.2 V 50 Ah 3.2 V 50 Ah
Module configuration 20S1P 20S1P 16S1P 16S2P
Module nominal energy (kWh) 6.4 6.4 2.56 5.12
Module dimensions (mm) 440 × 149 × 590 440 × 149 × 590 490 × 220 × 463 424 × 240 × 945
Rack configuration 100S1P–160S1P (5–8 packs) 100S1P–160S1P (5–8 packs) 96S1P–160S1P (6–10 packs) 96S2P–160S2P (6–10 packs)
Rack nominal energy (kWh) 32–51.2 32–51.2 15.36–25.6 30.72–51.2
System nominal energy range (kWh) 32–307.2 32–307.2 15.36–153.6 30.72–307.2

Energy ranges depend on module count and parallel racks. Discharge-rate labels do not guarantee a specific backup duration; calculate runtime using the required load, voltage window, usable energy and applicable operating limits.

Configuration and Compatibility Review

  • UPS manufacturer and exact model, DC voltage window and permitted charging settings.
  • Critical load, backup duration, discharge profile and reserve requirement.
  • Battery module count, rack arrangement, cooling and installation constraints.
  • Communication protocol, status monitoring, alarms and protection coordination.
  • Configuration-specific drawings, technical documents and commissioning requirements.

The catalog lists air cooling and communication options including Ethernet, RS485, CAN and 4G. Confirm the interfaces supplied for the selected system and verify compatibility with the connected UPS.

Review Your UPS Battery Requirement   View Technical Document Requests

Key Features of High-Rate LiFePO4 UPS Batteries

Wiren provides high-rate LiFePO4 UPS battery solutions with 1C, 2C and 4C discharge options. The UPS battery series includes UPS1C6, UPS2C6, UPS4C2 and UPS4C5 models, designed for different backup power requirements. With modular battery packs, flexible rack configurations, and battery management technology, these lithium UPS battery systems are suitable for data centers, hospitals, commercial buildings, and industrial applications.

Explore Wiren's Commercial and Industrial Energy Storage Solutions for more battery systems designed for different energy storage and backup power requirements.

  • Multiple Discharge Rates: 1C, 2C and 4C UPS battery options for different power requirements.
  • LiFePO4 Technology: Lithium iron phosphate battery chemistry for stationary backup applications.
  • Modular Design: Flexible battery module and rack configurations.
  • System Monitoring: BMS monitoring and multiple communication options.
  • Flexible Capacity: Expandable configurations according to UPS load and backup requirements.

 

1C, 2C and 4C High-Rate UPS Battery Options

Different UPS applications require different battery discharge capabilities. Wiren offers multiple high-rate lithium UPS battery models to match different power requirements.

  • 1C UPS Battery: UPS1C6 provides a 1C discharge option for compatible backup power applications.
  • 2C UPS Battery: UPS2C6 offers a higher discharge rate for UPS systems with greater power demands.
  • 4C UPS Battery: UPS4C2 and UPS4C5 are designed for applications requiring higher battery discharge rates.

Choosing the right high-discharge-rate UPS battery requires evaluating the UPS voltage range, connected load, discharge current, and required backup duration.

 

Applications of Lithium UPS Battery Systems

UPS Battery for Data Centers and Server Rooms

Data centers and server rooms require reliable backup power to protect servers, network equipment, and critical IT infrastructure. High-rate LiFePO4 UPS batteries provide battery backup options for compatible uninterruptible power supply systems.

Hospital and Medical Equipment Backup

Hospitals rely on backup power for essential medical equipment, monitoring systems, and critical electrical loads. Lithium UPS battery systems can be configured according to equipment power requirements and backup duration.

Commercial Buildings and Critical Infrastructure

Commercial buildings, communication facilities, and smart infrastructure require dependable backup power for essential electrical equipment. Modular UPS battery systems offer flexible configurations for different installation requirements.

Industrial UPS Backup Systems

Factories and industrial facilities use UPS backup systems to support control equipment, automation systems, and other critical loads during power interruptions.

 

Modular and Rack-Mounted UPS Battery Systems

Wiren's modular LiFePO4 UPS battery solutions support different battery module and rack configurations. Multiple modules can be combined to achieve the required system voltage and energy capacity according to the selected model.

The UPS battery systems also offer communication options including Ethernet, RS485, CAN, and 4G, depending on the configuration. These interfaces support battery monitoring and communication with compatible UPS or external management systems.

Before purchasing a rack-mounted UPS battery system, confirm the battery voltage, UPS compatibility, rack dimensions, communication protocol, and installation requirements.

 

Frequently Asked Questions About LiFePO4 UPS Batteries

1. What Is a High-Rate LiFePO4 UPS Battery?

A high-rate LiFePO4 UPS battery is designed to deliver relatively high discharge current for backup power applications. It is suitable for UPS systems with specific high-power discharge requirements.

2. What Is the Difference Between 1C, 2C and 4C UPS Batteries?

1C, 2C and 4C represent different battery discharge-rate ratings. Higher C-rates indicate a higher discharge current relative to rated battery capacity. The appropriate option depends on the UPS load and battery operating limits.

3. Can LiFePO4 Batteries Be Used in Existing UPS Systems?

LiFePO4 batteries can be used with compatible UPS systems. Buyers should verify DC voltage range, charging settings, BMS communication, discharge requirements, and battery protection compatibility before replacement.

4. How Do I Choose the Right UPS Battery Capacity?

Consider the UPS rated power, actual connected load, required backup time, battery voltage, and available installation space. These details help determine the appropriate battery model and rack configuration.

 

Recommended Products

Wiren Shenzhen Co., Ltd.